1992 Control of Vapor Temperature of OTEC by Using Reduced Order Models
An appropriate control strategy for an OTEC plant is required to attain a high efficiency and stability. This paper describes control of vapor temperatures at turbine inlet and outlet of the OTEC plant by using reduced order models based on the pole placement regulator. We constructed two reduced models so that the turbine inlet temperature was controlled by the warm sea water pump and the turbine outlet temperature was controlled by the cold sea water pump.